Quantcast
Channel: OpenPlant | AutoPLANT
Viewing all articles
Browse latest Browse all 16985

Wiki Page: How to Control Socket Weld Symbols in OpenPlant Isometrics Manager

$
0
0
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.5xx Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Bentley Product Advantage Group Background In Plant Design, few users avoid showing Socket Weld graphically in the Isometrics, which means other weld symbol like Butt weld will be shown. To achieve this requirement minor change in Schema is required. The steps are applicable to both AutoPLANT Modeler and OpenPlant Modeler with OpenPlant Isometrics Manager. Below steps are described in context with both AutoPLANT Modeler and OpenPlant isometrics Manager * OpenPlant Modeler & OpenPlant Isometrics Manager. Image Showing Socket Weld before modification. Using AutoPLANT Modeler & OpenPlant Isometrics Manager Steps to Accomplish Using Class editor Open "OpenPlant_3D.01.04.ecschema" schema and supplement it with "OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04. ecschema". See Default path mentioned below for Imperial project: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant\schemas Using "Find Class" button search class ' PIPING_FASTNER_SOCKET_WELD '. In Isometric Mapping change, " Is Skip " from False to True as see below. Save & Close Schema. Generate Isometrics & verify results. Socket welds will not be shown in the Isometrics see below image. Using OpenPlant Modeler & OpenPlant Isometrics Manager Steps to Accomplish In Class editor Open "OpenPlant_3D.01.04.ecschema" schema and supplement it with "OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04. ecschema" & "OpenPlant_3D_Supplemental_Modeling.01.06.ecschema". See Default path mentioned below for Metric Project: %ProjectRoot%i\WorkSpace\Projects\OPModeler_Metric\DataSet\Schemas Using "Find Class" button search class " PIPING_FASTNER_SOCKET_WELD" . In Isometric Mapping change, " Is Skip " from False to True as see below. Again Navigate to JOINT class, go to Join Type[2] for joint name SOCKET_WELD_JOINT . In Fastener field, replace WELD class to " PIPING_FASTNER_SOCKET_WELD" . See image below. Save & Close Schema. Launch OpenPlant Isometrics Manager. Generate Isometrics & Verify Results. See image below. Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

Viewing all articles
Browse latest Browse all 16985

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>