Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404/417 Environment: Windows 7 32/64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Background AutoPLANT component class needs to be properly mapped to the most suitable component classes available in the Open PLANT 3D schema to avoid below error . For example, Mapping of new component, say AT_GAUGE_HORIZ can be mapped under ‘Gauge’ class. Steps to Accomplish: In Class Editor, open s chema OpenPlant_3D.01.04.ecschema.xml. Supplement it with OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04.ecschema.xml. To Search for ' Gauge' class, type 'GAUGE in search option. See image below; 4. Expand Gauge Class to select 'Pressure Gauge' class. Under Autoplant_PDW_Class_Map custom attribute, add class name AT_GAUGE_HORIZ and module name AT_INSTR. See image below. 6. Save Schema. 7. Extract isometrics and verify the results. Isometrics gets generated without any error. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧