Quantcast
Channel: OpenPlant | AutoPLANT
Viewing all articles
Browse latest Browse all 16985

Wiki Page: ATDB0755

$
0
0

  
 Applies To 
  
 Product(s):AutoPLANT Piping
 Version(s):08.11.08.151
 Environment: N/A
 Area: General
 Subarea: 
 Original Author:Artiom Jakubovic, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

Following error messages are shown when I tried to open Piping model.



Pressing yes will return this message once again If I press “NO” next messages will be shown:





As a result Piping will not load.

Reason

Missing Config folder from %PROJECT_ROOT%. PROJECT_ROOT is variable, which is used within AutoPlant, for project folder location

 Steps to Resolve

Search project root for Config folder, it could be that it was accidently dragged to other folder. Or copy Config folder from project with same configuration, in this case some additional configuration changes will be required. The changes will depend upon project configuration.

 