Product(s): | AutoPLANT Piping | ||
Version(s): | 08.11.08.151 | ||
Environment: | N/A | ||
Area: | General | ||
Subarea: | |||
Original Author: | Artiom Jakubovic, Bentley Technical Support Group | ||
Problem Description
Following error messages are shown when I tried to open Piping model.
Pressing yes will return this message once again If I press “NO” next messages will be shown:
As a result Piping will not load.
Reason
Missing Config folder from %PROJECT_ROOT%. PROJECT_ROOT is variable, which is used within AutoPlant, for project folder location
Steps to Resolve
Search project root for Config folder, it could be that it was accidently dragged to other folder. Or copy Config folder from project with same configuration, in this case some additional configuration changes will be required. The changes will depend upon project configuration.