Applies To Product(s): OpenPLANT Orthographics Manager Version(s): 08.11.09.564 Environment: Windows 7 64 bit Area: General Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group Introduction When using Mixed pipe (OpenPLANT model having equipment and piping for example) to create General arrangement drawings the output might have missing dimensions of say equipment, etc. if not located correctly. Steps to Accomplish The problem arises because the OpenPLANT model is stored in folder ”Pipe” in Orthograhic Manager project. See below image where equipment, piping, structural models are placed under only one folder. Solution Ideally, they should be placed under separate folders i.e. pipe, Equipment, Structural, etc. In case of mixed pipe OpenPLANT model it should be placed in “Other” folder. This will enable correct dimensioning of all the entities. Correct Result: GA drawing of Mixed OpenPLANT model located under “Other” folder Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧