Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: - Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview In OpenPlant Isometrics Manager, during loading an i Model, it displays Failed to load 1 out of 1 i-models. Problem Description In OpenPlant Isometrics Manager, user might receive an error as described below: Error: i-model master unit 'Feet' is not matching with 'MILLIMETERS', specified as PROJ_MASTER_UNIT in OPModeler_MMetric project pcf. You might have selected wrong workspace project or i-model. Below steps will aid user to avoid such errors. Below example and error caused shown here using OpenPlant Modeler and OpenPlant Isometrics Manager. Steps to Resolve The above errors mentioned due to wrong selection of Project unit or using wrong I model processed in different project unit. User has to ensure the correct Project unit and its corresponding I model. Check list Close and Re-launch OpenPlant Isometrics Manager. Select correct Project unit say OPModeler_MMetric in this case. Ensure while navigating for an I model which should be present inside same Project folder. I.e. OPModeler_MMetric. Launch OpenPlant Isometrics Manager. Select an I model and verify results. Note – This error will not appear when opening a Metric Project and loading an I model of Mixed Metric project or Vice Versa. So user need to be careful and ensure that they are opening a correct file to process. Still a Problem? If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧