Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: - Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview In OpenPlant Isometrics Manager, during loading an i Model, it displays Error: Could not start IMODEL Engine Process in 60 seconds. Problem Description In OpenPlant Isometrics Manager, user might receive an error as described below: Error: Could not start IMODEL Engine Process in 60 seconds. Loaded 0 out of 1 i-models Below steps will aid user to avoid such errors. Below example and error caused shown here using OpenPlant Modeler and OpenPlant Isometrics Manager. Steps to Resolve The above errors mentioned due to missing ‘System’ folder present inside the Workspace folder which is found under OpenPlant Modeler V8i. User has to ensure the folder should be present and with correct nomenclature. See image below. Check list Navigate to OpenPlant Modeler V8i workspace. Check for System folder. Rename if ‘System’ folder name is incorrect. Paste it from default project installed. Re-install OpenPlant Modeler and check if system folder got installed. See below image with correct Folder settings. Launch OpenPlant Isometrics Manager. Select an I model and verify results. Still a Problem? If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧