Applies To Product(s): OpenPLANT Isometric Manager Version(s): 08.11.XX.XXX Environment: Windows 7 32/64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Background Weld summary is required in isometric to calculate the weld quantity in project. Following illustrative steps helps to get weld summary report to sum up the welds according to the weld type. Steps to Accomplish 1. Open report.def file below example is the path for default Metric project. C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\Isometrics\styles\IFC\config 2. Add below highlighted entry. 3. Save the file and generate isometric to review the result. See Also Configuring the BOM and Reports - http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12642.configuring-the-bom-and-reports Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU! .
↧