Forum Post: RE: Isometric Drawings

Hi Alex, Please check for stop signs. Also, make sure correct connection criteria is defined. Regards Dinesh

View Article


Forum Post: RE: European DIN Standards

Hi Maciej, If you are referring to pipe supports in ProSteel the answer is no. We are developing an Engineered Support Modeler tool that will work independently of ProSteel. It will work with...

View Article


Forum Post: RE: AutoPLANT Tap in branch on elbow with same BOP as Main Pipe

Thanks Dinesh, got it sorted.

View Article

Forum Post: RE: Autoplant Selections Dialog

thanks Artiom, why would the variables be missing from a model? Regards Ken

View Article

Forum Post: RE: AutoPLANT spool id in pcf

Hi Artiom, Use dthe assign Spool ID in Autoplant to give the pipe run spool identifiers an dthey come out on the PCF. Regards Ken

View Article


Forum Post: AutoPLANT Isogen tapped connection scale

Hi, The scale of vents and drains is to small to read, how can I increase the size. These are on tapped connections.

View Article

Forum Post: RE: Tag customizing

Ronit, If this is a KKS tag format then I suggest you download the KKS workspace environment that we have created. Under our agreement with the KKS organization we are not able to deliver this as an...

View Article

Forum Post: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION

Hi, Our designers wan tto change the default description for Misc Attachement Floor Openeing to Thru Wall so they don't have to edit it each time. I see that under CLASS_OOB.ini there is a Long and...

View Article


Forum Post: RE: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION

Hello Ken, After changing the CLASS.ini all the new Misc attachment placed  will have the new class description. You will need to update the Short_desc and Long_desc of the Misc attachments you had...

View Article


Forum Post: RE: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION

Hi kfitz, Changing SHORT/LONG descriptions in class.ini file [AT_ATTACH_FLOOROPENING] should change the default settings in AutoPLANT when placing new attachments. If it did not change, please make...

View Article

Forum Post: OpenPlant Modeler - Piping new custom component

Hello, we want to create a new custom component for piping which should have our defined facings. It seems we need to add our facing inside of FACING_VALUE_MAP but where could I find this Value Map?...

View Article

Forum Post: RE: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION

Thanks Guys, I changed the long and short description on the project class.ini but stil coming out with previous descriptions, strange one. Ken

View Article

Forum Post: Weld ID

Hi, I am assigning weld ID's to a piping model by type but it is limited in the types you can choose. For example Field Weld do not have a separate weld number type i.e. FW1 as they fall under Butweld...

View Article


Forum Post: RE: OpenPlant Modeler - Piping new custom component

The FACING_VALUE_MAP is located inside of the OpenPlant Catalogue schema. shaun

View Article

Forum Post: RE: MISC ATTACHEMENTS FLOOR OPENING DESCRIPTION

Can you please attach your updated class.ini file here and also tell us what is it's exact location within the project folder?

View Article


Forum Post: RE: Autoplant Selections Dialog

Hi Ken, Unfortunately, I do not know what could cause this. I could assume that some how dwg's XDATA was removed due to AutoCAD crash, maybe due to some manipulations withe the model. To my regret it...

View Article

Forum Post: RE: AutoPLANT Isogen tapped connection scale

Hello Ken, Most of the ISOGEN symbols can be scaled using Symbol Editor. Check if symbols are  User Definable in C:\Program Files (x86)\Bentley\Plant V8i\Help\Isogen\Symbol Keys.pdf (path in 64 bit...

View Article


Forum Post: Can we install and use Bentley Autoplant ss4 v8i and Aveva PDMS...

Dear Bentley Team, Can we Install and use Bentley Autoplant ss4 v8i and Aveva PDMS on our same workstation ? Whether any files will clash/corrupt by installing both software on same workstation ? What...

View Article

Forum Post: RE: OpenPlant Modeler - Piping new custom component

Thanks for this quick answer. I checked all OpenPlant Catalogue schemas but the facing which is used for custom component is not included to this schemas. Could you tell where I could find the default...

View Article

Forum Post: RE: OpenPlant Modeler - Piping new custom component

Yvonne, I am unsure exactly what you are looking for. The facing value map would hold all definitions for facings used. You may add to this list to create any new ones you may need. It looks like...

View Article