Forum Post: RE: AutoPlant Project Packager
Hello Justinas, Yes, it worked and I could pack project without any issue. I never thought that I would need to enable AutoPlant project for OpenPlant isometrics. Thanks for your help. Regards Atul
View ArticleForum Post: Isometric Drawings
Hello, I am using AutoPLANT vesrion 08.11.09.140 Please see the attached model. There are 2 PXF: "200-PP-12-SW-018_partial model.pxf" and "PT 5000 PIPING MODEL_00096-2014_06_17-only_18-Full.PXF". The...
View ArticleWiki Page: Flanges are not automatically placed for flanged valves using...
Applies To Product(s): AutoPLANT Piping Version(s): 08.11.09.140 Environment: Windows 7 32 bit, Windows 7 64 bit, Windows XP 32 bit, Windows XP 64 bit Area: Component Subarea: N/A Original Author:...
View ArticleForum Post: RE: AutoPLANT spool id in pcf
Hello Ken, if the spools are defined in Piping Components then they should be listed as SPOOL-IDENTIFIER in PCF file. However different option are available in isogen to output spool id. Check Option...
View ArticleForum Post: conversion of a model from Autocad plant 3D (Autodesk) to...
1. Is it possible to interface 3D design ,spec, etc... modules from AUTOCAD PLANT3D to AUTOPLANT 3D(BENTLEY) and vice versa? 2. What are the frameworks being used for AUTOCAD PLANT3D and AUTOPLANT...
View ArticleForum Post: RE: AutoPLANT V8i (SELECTseries 6) is LIVE
When will the AutoPlant P&ID be updated for Acad 2014 SS6? And what should be done in the meantime?
View ArticleForum Post: RE: Running OPIM with AutoPLANT
I agree..... the seed file should be editable in AutoCAD. I am able to pull iso but some things that were in IsoGen are missing like a call out for nozzles and all the other text has boxes around...
View ArticleForum Post: RE: AutoPLANT spool id in pcf
Thanks Artiom, Those switches only tell Isogen to output Spool ID. I have the relevant ones ticked but while the Sool ID comes out int he isometric they are not in the PCF. Ken
View ArticleForum Post: AutoPLANT V8i Isogen Support symbol
When I run an isometric in AutoPLANT through isogen all my Supports symbols are coimg out as two parallel line (see example 1 on attachement). This is fine for most supports but I want to show my Base...
View ArticleForum Post: RE: AutoPLANT V8i Isogen Support symbol
Hi Kfitz, In order change the representation of the component in the Iso the symbol needs to be modified. Please find below link which will guide to the steps....
View ArticleForum Post: RE: OPPID : relationships
Good morning Tony, Sorry to append to an already answered question. But I have been looking into the "relationship class mapping list". Can you tell me the difference between a "System Relationship"...
View ArticleForum Post: RE: AutoPLANT V8i Isogen Support symbol
Thanks Dinesh, These are not custom symbols as they are already in the out of the box Autoplant Ken
View ArticleForum Post: RE: conversion of a model from Autocad plant 3D (Autodesk) to...
AutoPLANT does not have a mechanism to import or export with AutoCAD Plant 3D. Please contact Autodesk for info on what Plant 3D will import or export.
View ArticleForum Post: RE: OPPID : relationships
Wim Aerts, First the RELATIONSHIP_CLASS_CRITERIA_STRUCTURE needs to be defined. This is generally used to map a CAD relationship to a data exchange relationship. In this context then we can define the...
View ArticleForum Post: Converting AutoPLANT dwg file to brief case mode programatically
Hi all, I have a scenario where i need to convert hundreds of AutoPLANT files to brief case mode. Is there any automated way or API to do that programatically? Thanks, Sona De
View ArticleForum Post: Reporting from OPModeler and OPReporting giving different results
Ive created two exact ECQUERYs( ALL PIPECOMPONENTS)...one in OPModeler and one in OPReporting. In OPmodeler ive referenced out everything meaning only the single UNIT that exists in the repository. In...
View ArticleForum Post: RE: Converting AutoPLANT dwg file to brief case mode programatically
For 3D AutoPLANT drawings the existing tool Relationship manager can be used to move multiple documents to a Configuration Project (Brief Case Mode). Basic steps Start Relationship Manager Change the...
View ArticleWiki Page: Cannot Update Calculated Bolt Lengths in Description Field
Applies To Product(s): Bentley OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: N/A Original Author: Rahul Kumar, Bentley Technical Support Group...
View ArticleWiki Page: How To Label Valve Tag
Applies To Product(s): Bentley OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original...
View Article