File: AutoPLANT V8i (SELECTseries 6) Readmes
Following Readme files for the latest releases AutoPLANT V8i (SELECTseries 6) products have been zipped as 'AP-SS6-ReadMeFiles.zip': AutoPLANT_Modeler_ReadMe.chm AutoPLANT_Prerequisites_ReadMe.chm...
View ArticleForum Post: PowerPid and Projectwise
Good morning, Are there any guidelines on how to integrate PowerPid in Projectwise? For some reason this doesn't seem to work. Kind regards.
View ArticleForum Post: OPPID SS5: adding jumper to crossing pipes
Good morning, When I draw horizontal and vertical pipes, then the vertical pipes are cut where they cross the horizontal pipes. Is there a setting to determine the size of the cut? Kind regards.
View ArticleForum Post: RE: PowerPid and Projectwise
Hello Wim, And what exactly do you mean by integrating? Using PW Managed workspace? Just storing files in PW? Integrating Plant project (and database) to PW? Some other idea of integration? Please...
View ArticleForum Post: RE: OPPID SS5: adding jumper to crossing pipes
Hello Wim, Please check this article on more details how you can customize default pipe jumper in OPPID: communities.bentley.com/.../3410.aspx Let me know if you need more details/help with this....
View ArticleForum Post: RE: PowerPid and Projectwise
Hello Justinas, We are just trying to open PowerPid drawings from within ProjectWise. We do not use Managed Workspaces, we have adapted the standard metric workspace to suit our needs. We don't use...
View ArticleForum Post: RE: OPPID SS5: adding jumper to crossing pipes
Hello Justinas, I read the article, That did the trick, I can now change the size of the gap. Thank you! Now this is out of the way I bump up to an other problem. I know I can reapply the jump in an...
View ArticleForum Post: RE: PowerPid and Projectwise
Hello Wim, I see now. If you are not using managed workspace in PW, it would be then good idea to create a workspace profile for your OPPID project and assign it to you OPPID files in PW, so that all...
View ArticleForum Post: RE: OPPID SS5: adding jumper to crossing pipes
Hello Wim, Good to hear that initial question is now resolved. As for this error, it would usually indicate that there might be some issues in the schema files regarding either pipe runs or jumper...
View ArticleForum Post: RE: How to change project Name
Hello Eric, When you change project name in this window and save the changes (File- Save) it should store the changes for the next time you'll open this. Do you get any errors or something when you...
View ArticleForum Post: RE: PowerPid and Projectwise
Hello Justinas, This looks like it could be helpfull. Unfortunately I'm not going to have a change to work on this for a couple of days. I'm going to try this out next week! I'll keep you posted....
View ArticleForum Post: RE: OPPID SS5: adding jumper to crossing pipes
Hello Justinas, I had these errors before too, I thought they were a result of the gap settings. I don't think this is about the schema's, I am having the same problems with this drawings in other...
View ArticleForum Post: RE: OPPID SS5: adding jumper to crossing pipes
Hello Wim, Thanks for the schema files. If you say it's only occurring with some converted from PSPID pipes, could you please also send one sample model which I could check it with? Regards, Justinas
View ArticleForum Post: RE: OPPID SS5: adding jumper to crossing pipes
Hello Justinas, Here is an example file. Kind regards.
View ArticleForum Post: RE: How to change project Name
Hi , When I change project name, It changes in the project tree ( on the left), but if I close and open Project Administrator, the name in the project tree is still the old one. But the name in...
View ArticleForum Post: AutoPlant - Generating Reports/BOM - removing the feet/inches...
Hi, Using AutoPlant V8i (SS5) and generating BOM reports for PM. He is specifically looking for pipe lengths and would like to easily total them up in Excel. When the report is generated in Imperial...
View ArticleForum Post: RE: AutoPlant - Generating Reports/BOM - removing the feet/inches...
We had this same issue and I was able to get around it by changing my report to pull the pipe_len field instead of the cut_len field. Cut_len is converted into feet and inches, where as pipe_len will...
View ArticleForum Post: Four questions on Isometric Drawings set up !
In the general effort of setting up the isometric drawing of my company I have four questions: 1) How can I set up the elbows to be depicted with curve and not with angle? 2) What happens with the...
View ArticleForum Post: RE: Four questions on Isometric Drawings set up !
Hello Manolatos, Could you provide more details on which application are you trying to do this? AutoPLANT with ISOGEN? AutoPLANT with OpenPlant Isometrics Manager? OpenPlant Modeler? Which version of...
View ArticleForum Post: AutoPlant Project Packager
I am using AutoPlant Project Packager to pack and create backup of the project. It was working fine for last 3 years. However now it gives error as "Error in Pack function: File already exists" and...
View Article