Forum Post: RE: Valve TagNumber to inherit property from Pipeline

I still can't seem to get this working. The Properties on my Pipeline, PipeRun and Fluid Regulator (Valve) are all new properties currently not existing in the schemas. I have added the new Property...

View Article


Wiki Page: OPPID - How to setup a mixed Metric environment

      Introduction This document will explain how to setup a mixed metric environment with metric project workspace which is delivered as OPPowerPID_Metric in  OPPID. The project OPPowerPID_Metric...

View Article


Forum Post: RE: how to generate P&ID plans Automatically from 3D Model in...

MIso, This is not possible with Bentley applicaitons - you cannot convert or auto-create a PID from a OpenPlant 3D model. Regards, Tony DeRosa Bentley Plant

View Article

Forum Post: RE: Valve TagNumber to inherit property from Pipeline

Hello Melissa, Can you provide a few examples of what it is you need? Actual tag formats. A question - is COMMODITY_CODE a property similar to PLANT_AREA or is this a regular property like...

View Article

Forum Post: RE: Valve TagNumber to inherit property from Pipeline

Melissa, Attached you will find the updated version of the document on how to pass an Associated Item between components. As noted in the document - This will work for ASSOCIATED ITEMS only and NOT a...

View Article


Forum Post: RE: Valve TagNumber to inherit property from Pipeline

Hello Tony, COMMODITY_CODE is a regular property like DESIGN_PRESSURE or DESCRIPTION. I do not want to make it an Associated Property like PLANT_AREA as only my pipeline and valve will have this...

View Article

Forum Post: RE: Bushing

Hello Alex, Thank you for additional information, it helped a lot. I have edited bushing drawing ebs file to meet current requirements. It seems that by default bushing thread engagement should be...

View Article

Forum Post: RE: how to generate P&ID plans Automatically from 3D Model in...

Is this an applicable workflow in your business? I know the PID being there first and the modelling done subsequently.

View Article


Forum Post: RE: AutoPLANT Flattener SS5 on AutoPLANT SS4 Design

Hello Alex, I don't have any relevant information regarding this case. As well there is not much that could be done from Technical Support Group regarding product licencing policy. Possibly,...

View Article


Forum Post: RE: Valve TagNumber to inherit property from Pipeline

Hello Melissa, Can you try using the following expression for the calculated ECExpression in your VALVE class, COMMODITY_CODE property, to get the same property from the PIPING_NETWORK_SYSTEM class:...

View Article

Forum Post: RE: OpenPlant isometrics manager and PCF file input

Hello Maciej, As far as I know, there are no immediate plans to include a possibility to have PCF as an input format for OpenPlant Isometrics Manager. We can only generate PCF as an additional output...

View Article

Forum Post: RE: Valve TagNumber to inherit property from Pipeline

Melissa, To be clear - Associated Items do not have to be assigned to every component. You can select which components use each Associated item. Wih that said - If the suggestion from JustinasL works...

View Article

Forum Post: RE: Valve TagNumber to inherit property from Pipeline

Thank you Justinas, that works on my side as well. And thank you as well Tony.

View Article


Forum Post: RE: Valve TagNumber to inherit property from Pipeline

Great to hear that I could help and also that it works well for you as well. Regards, Justinas

View Article

Forum Post: RE: Autoplant General Arrangement (GA) drawiing in Document Manager

thanks again guys, This is a tricky question. We have created a relationship called SHT_No so the designer can break down his line for isometric purposes by Line number and Sht No. He will have the...

View Article


Forum Post: Changing the Look of Parametric Symbols in OPM

Hi All Is it possible to change the way OpenPlant Modeller draws the parametric symbols.  In PlantSpace design series you could change the rule files to get a different look and also create some...

View Article

Forum Post: Valve body not displaying with certain Tagging (NAME) Convention??

I am working with Bentley(R) OpenPlant PowerPID V8i (SELECTseries 5) - Version 08.11.10.202 I have added 2 properties to my FLUID REGULATOR class that gets its information automatically from my...

View Article


Forum Post: RE: Changing the Look of Parametric Symbols in OPM

Hello Spyker, Each of the visual plant components class in OpenPlant does have a Creation Attribute custom attribute (usually in Supplemental_Modeling schema) which controls how is that component...

View Article

Forum Post: RE: Valve body not displaying with certain Tagging (NAME)...

Hi Melissa, Can you try removing the Parser regular expression, leaving it empty, as you do retrieve your FLUID_COMMODITY_CODE & PIPELINE_NUMBER from PIPING_NETWORK_SYSTEM, so it should not be...

View Article

Forum Post: RE: Valve body not displaying with certain Tagging (NAME)...

Hello Justinas, Thank you, that does work. :) The only thing then is, when wanting to edit the Valve Number again, it does not bring up the original pop-up dialog box that it did when you have a...