Forum Post: RE: Valve TagNumber to inherit property from Pipeline
I still can't seem to get this working. The Properties on my Pipeline, PipeRun and Fluid Regulator (Valve) are all new properties currently not existing in the schemas. I have added the new Property...
View ArticleWiki Page: OPPID - How to setup a mixed Metric environment
Introduction This document will explain how to setup a mixed metric environment with metric project workspace which is delivered as OPPowerPID_Metric in OPPID. The project OPPowerPID_Metric...
View ArticleForum Post: RE: how to generate P&ID plans Automatically from 3D Model in...
MIso, This is not possible with Bentley applicaitons - you cannot convert or auto-create a PID from a OpenPlant 3D model. Regards, Tony DeRosa Bentley Plant
View ArticleForum Post: RE: Valve TagNumber to inherit property from Pipeline
Hello Melissa, Can you provide a few examples of what it is you need? Actual tag formats. A question - is COMMODITY_CODE a property similar to PLANT_AREA or is this a regular property like...
View ArticleForum Post: RE: Valve TagNumber to inherit property from Pipeline
Melissa, Attached you will find the updated version of the document on how to pass an Associated Item between components. As noted in the document - This will work for ASSOCIATED ITEMS only and NOT a...
View ArticleForum Post: RE: Valve TagNumber to inherit property from Pipeline
Hello Tony, COMMODITY_CODE is a regular property like DESIGN_PRESSURE or DESCRIPTION. I do not want to make it an Associated Property like PLANT_AREA as only my pipeline and valve will have this...
View ArticleForum Post: RE: Bushing
Hello Alex, Thank you for additional information, it helped a lot. I have edited bushing drawing ebs file to meet current requirements. It seems that by default bushing thread engagement should be...
View ArticleForum Post: RE: how to generate P&ID plans Automatically from 3D Model in...
Is this an applicable workflow in your business? I know the PID being there first and the modelling done subsequently.
View ArticleForum Post: RE: AutoPLANT Flattener SS5 on AutoPLANT SS4 Design
Hello Alex, I don't have any relevant information regarding this case. As well there is not much that could be done from Technical Support Group regarding product licencing policy. Possibly,...
View ArticleForum Post: RE: Valve TagNumber to inherit property from Pipeline
Hello Melissa, Can you try using the following expression for the calculated ECExpression in your VALVE class, COMMODITY_CODE property, to get the same property from the PIPING_NETWORK_SYSTEM class:...
View ArticleForum Post: RE: OpenPlant isometrics manager and PCF file input
Hello Maciej, As far as I know, there are no immediate plans to include a possibility to have PCF as an input format for OpenPlant Isometrics Manager. We can only generate PCF as an additional output...
View ArticleForum Post: RE: Valve TagNumber to inherit property from Pipeline
Melissa, To be clear - Associated Items do not have to be assigned to every component. You can select which components use each Associated item. Wih that said - If the suggestion from JustinasL works...
View ArticleForum Post: RE: Valve TagNumber to inherit property from Pipeline
Thank you Justinas, that works on my side as well. And thank you as well Tony.
View ArticleForum Post: RE: Valve TagNumber to inherit property from Pipeline
Great to hear that I could help and also that it works well for you as well. Regards, Justinas
View ArticleForum Post: RE: Autoplant General Arrangement (GA) drawiing in Document Manager
thanks again guys, This is a tricky question. We have created a relationship called SHT_No so the designer can break down his line for isometric purposes by Line number and Sht No. He will have the...
View ArticleForum Post: Changing the Look of Parametric Symbols in OPM
Hi All Is it possible to change the way OpenPlant Modeller draws the parametric symbols. In PlantSpace design series you could change the rule files to get a different look and also create some...
View ArticleForum Post: Valve body not displaying with certain Tagging (NAME) Convention??
I am working with Bentley(R) OpenPlant PowerPID V8i (SELECTseries 5) - Version 08.11.10.202 I have added 2 properties to my FLUID REGULATOR class that gets its information automatically from my...
View ArticleForum Post: RE: Changing the Look of Parametric Symbols in OPM
Hello Spyker, Each of the visual plant components class in OpenPlant does have a Creation Attribute custom attribute (usually in Supplemental_Modeling schema) which controls how is that component...
View ArticleForum Post: RE: Valve body not displaying with certain Tagging (NAME)...
Hi Melissa, Can you try removing the Parser regular expression, leaving it empty, as you do retrieve your FLUID_COMMODITY_CODE & PIPELINE_NUMBER from PIPING_NETWORK_SYSTEM, so it should not be...
View ArticleForum Post: RE: Valve body not displaying with certain Tagging (NAME)...
Hello Justinas, Thank you, that does work. :) The only thing then is, when wanting to edit the Valve Number again, it does not bring up the original pop-up dialog box that it did when you have a...
View Article