Forum Post: RE: How Do I Remove a Spool Value?

Additionaly, to assign blank Spool id's. Please follow the steps below. 1. Go to 'Piping Piping Tools Assign Spool ID's...'. 2.Remove the value from 'Starting SpoolID' (i.e., it's blank), then check...

View Article


Forum Post: RE: Stub in at bend pipe

Thanks Artiom actually i've done this by editing isogen result by calculated manually the stub in position but when fit-up in field there are many error, hopefully there are any other idea to resolve...

View Article


Forum Post: RE: How Do I Remove a Spool Value?

Thanks guys! It worked!

View Article

Forum Post: AutoPLANT import .XML and .PID (ISO 15926) format from SP P&ID

Have read a few threads on this but there was no definitive answers Can AutoPLANT V8i ss4 import .XML data? How can we open a .PID formatted drawings? Thanks

View Article

Forum Post: Auto-Routing on pipe line placement

Hi, What is the current status of OpenPlant Autorouting functions, i.e. what can user expect from it.  Let's compare it to AutoPLANT Piping or others like Plant 3d if possible, please.

View Article


Forum Post: RE: OpenPlant Isometrics Manager to be run from inside of Modeler

Thanks!

View Article

Forum Post: Clash detection in OpenPlant Modeler

Hi,  Is there any real-time functionality of clash detection in real-time available/planned? Users would like to see real time advises from the systems if they are .eg. not to close to other pipes,...

View Article

Forum Post: OP Power P&ID OP Modeler data check in standalone mode

Hi,  Is there any possibility / workflow to do something like 2D 3D in AutoPLANT, i.e. verify which piping elements has been inserted into 3D model and get report about it, please? This is about using...

View Article


Forum Post: RE: Assembly Manager

Thank you.

View Article


Forum Post: RE: Autoplant hand valves tag prompt/dialog

If you Edit component and place the tag value in the TAG_NO field for a valve, it will be tagged on the iso. However the dialog that is opened for control valves that includes the button to browse for...

View Article

Forum Post: RE: Auto-Routing on pipe line placement

Hell Macej, There is Intelligent Line Manager in OpenPlant Modeler. This tool allows to create intelligent center-lines from line segments and smart-lines, and then insert OpenPlant components on...

View Article

Forum Post: RE: OP Power P&ID OP Modeler data check in standalone mode

Hello Maciej, OpenPlant Modeler is equipped with 2D to 3D Integration. From OpenPlant Help File: "2D to 3D Integration OpenPlant 2D to 3D integration lets you compare components in an OpenPlant...

View Article

Forum Post: IsoExtractor bill of material

How do you add the short description from Specification Maker to the bill of material in IsoExtractor? Is there a document that explains how to add columns and tags to the BOM?

View Article


Forum Post: Bentley Vision-like or AP Document Manager tool for OpenPlant

Hi, Is there available the simple tool that would help the user to gather together documents related to the same project, assuming that they work in standalone mode i.e. without ProjectWise?

View Article

Forum Post: OP Symbology Equipment

Good day, I was trying to modify the above Named Expression of OpenPlantmodeler.dgnlib, when I noticed the out of the box does not work properly. The supplied expression is: "BY_LEVEL_AND_TEMPLATE:"...

View Article


Forum Post: RE: Bentley Vision-like or AP Document Manager tool for OpenPlant

OpenPlant's primary file manager is ProjectWise.  There is no other tool to track files when using OpenPlant in standalone.  

View Article

Forum Post: RE: Barcode

kfitz hi, i using autoplant v8i ss3 and I would like to add a barcode to my isometrics when i run them through isogen. I can add the field I want to the POS file to get it to come out in the right...

View Article


Forum Post: RE: Autoplant hand valves tag prompt/dialog

Hello Ken, It seems this should be quite possible.  Valve input routine should be changed. I would recommend using input routine for control valves as example modules\base\common\cntinput.ebs. Default...

View Article

Wiki Page: Properties - Bentley OpenPlant PowerPID

View Article

Wiki Page: Using unicode in tags

      Applies To        Product(s): Bentley OpenPlant PowerPID   Version(s): N/A   Environment:  Windows 7 64 bit   Area:  Properties   Subarea:    Original Author: Artiom Jakubovic, Bentley Technical...

View Article