Forum Post: RE: How Do I Remove a Spool Value?
Additionaly, to assign blank Spool id's. Please follow the steps below. 1. Go to 'Piping Piping Tools Assign Spool ID's...'. 2.Remove the value from 'Starting SpoolID' (i.e., it's blank), then check...
View ArticleForum Post: RE: Stub in at bend pipe
Thanks Artiom actually i've done this by editing isogen result by calculated manually the stub in position but when fit-up in field there are many error, hopefully there are any other idea to resolve...
View ArticleForum Post: AutoPLANT import .XML and .PID (ISO 15926) format from SP P&ID
Have read a few threads on this but there was no definitive answers Can AutoPLANT V8i ss4 import .XML data? How can we open a .PID formatted drawings? Thanks
View ArticleForum Post: Auto-Routing on pipe line placement
Hi, What is the current status of OpenPlant Autorouting functions, i.e. what can user expect from it. Let's compare it to AutoPLANT Piping or others like Plant 3d if possible, please.
View ArticleForum Post: Clash detection in OpenPlant Modeler
Hi, Is there any real-time functionality of clash detection in real-time available/planned? Users would like to see real time advises from the systems if they are .eg. not to close to other pipes,...
View ArticleForum Post: OP Power P&ID OP Modeler data check in standalone mode
Hi, Is there any possibility / workflow to do something like 2D 3D in AutoPLANT, i.e. verify which piping elements has been inserted into 3D model and get report about it, please? This is about using...
View ArticleForum Post: RE: Autoplant hand valves tag prompt/dialog
If you Edit component and place the tag value in the TAG_NO field for a valve, it will be tagged on the iso. However the dialog that is opened for control valves that includes the button to browse for...
View ArticleForum Post: RE: Auto-Routing on pipe line placement
Hell Macej, There is Intelligent Line Manager in OpenPlant Modeler. This tool allows to create intelligent center-lines from line segments and smart-lines, and then insert OpenPlant components on...
View ArticleForum Post: RE: OP Power P&ID OP Modeler data check in standalone mode
Hello Maciej, OpenPlant Modeler is equipped with 2D to 3D Integration. From OpenPlant Help File: "2D to 3D Integration OpenPlant 2D to 3D integration lets you compare components in an OpenPlant...
View ArticleForum Post: IsoExtractor bill of material
How do you add the short description from Specification Maker to the bill of material in IsoExtractor? Is there a document that explains how to add columns and tags to the BOM?
View ArticleForum Post: Bentley Vision-like or AP Document Manager tool for OpenPlant
Hi, Is there available the simple tool that would help the user to gather together documents related to the same project, assuming that they work in standalone mode i.e. without ProjectWise?
View ArticleForum Post: OP Symbology Equipment
Good day, I was trying to modify the above Named Expression of OpenPlantmodeler.dgnlib, when I noticed the out of the box does not work properly. The supplied expression is: "BY_LEVEL_AND_TEMPLATE:"...
View ArticleForum Post: RE: Bentley Vision-like or AP Document Manager tool for OpenPlant
OpenPlant's primary file manager is ProjectWise. There is no other tool to track files when using OpenPlant in standalone.
View ArticleForum Post: RE: Barcode
kfitz hi, i using autoplant v8i ss3 and I would like to add a barcode to my isometrics when i run them through isogen. I can add the field I want to the POS file to get it to come out in the right...
View ArticleForum Post: RE: Autoplant hand valves tag prompt/dialog
Hello Ken, It seems this should be quite possible. Valve input routine should be changed. I would recommend using input routine for control valves as example modules\base\common\cntinput.ebs. Default...
View ArticleWiki Page: Using unicode in tags
Applies To Product(s): Bentley OpenPlant PowerPID Version(s): N/A Environment: Windows 7 64 bit Area: Properties Subarea: Original Author: Artiom Jakubovic, Bentley Technical...
View Article