Forum Post: AP OPIM - null reference

When I tried to run OPIM from AutoPLANT on a single pipe, component exportion looked OK, but get an null reference exception. Where I can find out what's the problem in order to fix it. Thanks, Maggie

View Article


Forum Post: OPPID - Auto Insert Annotation on Previously inserted Symbol

Hi, Does anybody know if its possible to make annotation appear automatically on drawing that was done previously? e.g. I have a drawing from weeks ago that has a bunch of instruments on it, I would...

View Article


Forum Post: Multiport Valve Component Dimension In OPIM

HI , I am trying to suppress multiport valve component dimension in OPIM, Please help, Regards, Vivek

View Article

Forum Post: RE: OPPID Synchronization Error : Parameters in RPC Request

Hi Krishna, I believe this issue is now resolved by Professional Services team. Please confirm. Regards, Harpreet

View Article

Forum Post: RE: Multiport Valve Component Dimension In OPIM

Hello Vivek, What Expression have you used for overrides? -Regards | Rahul Kumar

View Article


Forum Post: RE: AP OPIM - null reference

Hello Maggie, Could you please let us know on below queries to find out the root cause. 1. Have you recently installed any lates AutoPLANT/OpenPlant Isometric Manager version? 2. What version was used...

View Article

Forum Post: AP-imodel composer: I am not able to select a folder to save a...

I now have AP-imodel composer installed and running in AutoPLANT Modeler SS7. When I bring up the Publish I-model pane and tell it to create a package it allows me to then change the name of the...

View Article

Forum Post: RE: Multiport Valve Component Dimension In OPIM

HI Rahul, I used attached expression, the component changes it's level to defined level, but still getting individual dimensions. I was expecting Dimension=0 should work. Regards, Vivek

View Article


Forum Post: RE: AP OPIM - null reference

AutoPLANT 8.11.12.122 and OPIM 08.11.09.574 I know you may said they are not compatible, but this is on a on going project and I did not do the initial setup. Currently I am seeking a way to fix it :(

View Article


Forum Post: unconnected component_how to analysed Production Log massage?

Hi Bentley, I'm facing with unconnected component problem. It only simple piping model with 3 pipes and 2 elbows, but it failed to generate isometric dwg. Please refer photo attached. I view the...

View Article

Forum Post: Missing Pipeline Vertex Handler

Hi all, I'm trying to manipulate pipeline but it doesn't show vertex handler at all. Can anyone help me to have it? Thanks in advance. OhSung

View Article

Forum Post: RE: Missing Pipeline Vertex Handler

Hello Ohsung, You can check it by clicking "Disable Handles" under Element Selection Dialog. See image below. Hope this helps! -Regards | Rahul Kumar

View Article

Forum Post: RE: Missing Pipeline Vertex Handler

Thanks a lot!!!

View Article


Wiki Page: Error message on opening existing models in 08.11.09.564 build

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.564+ Environment: Windows 7 (64 bit) Area: Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Overview Whil e...

View Article

Forum Post: RE: Open Plant Support Engineering and AutoPIPE

Hello Jonatan, OpenPlant Support Engineering component cannot perform Copy operation in OpenPlant Modeler or vice versa. It is not supported. However there is partial working for Move command if you...

View Article


Forum Post: RE: Open Plant Support Engineering and AutoPIPE

Hello Jonatan, Based on above query on importing correct PXF file to AutoPipe, we have created a Service Request, SR # 7000454039 and filed a Defect # 360702 for this. This will further gets evaluated...

View Article

Forum Post: RE: unconnected component_how to analysed Production Log massage?

Hello Hasnuddin Yusof, What version of AutoPLANT Modeler and OpenPlant Isometric Manager version you are using? Please run connectivity checker to see the disconnects as below. As well send the...

View Article


Forum Post: RE: AP OPIM - null reference

I understand that Maggie. But, we are not sure if it will work as there is version mismatch of the schemas.

View Article

Forum Post: RE: Open Plant Support Engineering and AutoPIPE

thanks!

View Article

Forum Post: OPPID - Missing GUID - is there a utility to fix items where the...

Hi All, So we have a few instances where the GUID is blank in the OPPID drawing. As we know this is used by OPPID to link to the Plant Database, but when it is blank it has lost its link. I'm unsure...