Forum Post: OPIM - How many Maximum No Of Lines in BOM

HI, I am trying to find how many maximum no of lines BOM may have, as it starts with node 60, where it may ends?? Please help for the same. Regards, Vivek

View Article


Forum Post: RE: I need help creatin an angled pressure relief valve (inlet...

(Please visit the site to view this file)Thanks for your help Joey, here is the spec

View Article


Forum Post: RE: How to isolate piping 3D model by line number?

Thanks, this helped me.

View Article

Forum Post: AP OPIM - Multiline control valve tag

I tried to display control valve tag in ISO image and it did. However, it displayed as one line instead of multi-lines. Can someone help? Thanks, Maggie

View Article

Forum Post: RE: OPIM - How many Maximum No Of Lines in BOM

Hello Vivek, There are no certain criteria to limit the number of lines, as it may continue to produce the longer list depending on number of components in a drawing. User may tweak a little by...

View Article


Forum Post: RE: OPIM - How many Maximum No Of Lines in BOM

Thanks Rahul, I was intending to insert one table below BOM, just would like to make sure that it should not overlap with BOM at any point of time, But as there is already an enhancement filed, I would...

View Article

Forum Post: RE: AP OPIM - Multiline control valve tag

Hello Maggie, Multi lines can be done if you are using separate OpenPlant properties which should be relatively mapped with AutoPLANT Properties. See Below wiki where tagging has been done based on...

View Article

Forum Post: RE: OPIM - How many Maximum No Of Lines in BOM

Hello Vivek, You may create a service request as well if you wanted to share your thoughts on this for a better BOM management, which will help us to take discuss with development team. However one way...

View Article


Forum Post: Built own piping spec/class

Hii Bentley, I'm using Bentley Autoplant 3D SS5. I have one piping spec/class received from client (japan company). So i need to built my own piping spec/class based on client piping spec/class. The...

View Article


Forum Post: RE: OPIM - Symbol rotation

Hello Maggie, I believe you are having Isometric output as dwg. Please refer below wiki which shall help you through with this problem....

View Article

Wiki Page: OPIM- how to show welding points per 6 meters along straight pipe?

Hello, Purchased steel pipes are usually 6 meters, and will be welded on field. How to show those on field welding points on isometric drawings? Thank you.

View Article

Forum Post: RE: Changing the display of fasteners in AutoPLANT Modeler SS4

Hello Darren, Above requirement is possible but needs involvement using AutoPLANT component customization. I would recommend you to contact bentley Professional Services team to modify this item. I...

View Article

Wiki Page: Settings/Attributes- OpenPlant Isometrics Manager

Settings/Attributes - OpenPlant Isometrics Manager Settings/Attributes - OpenPlant Isometrics Manager To Discuss various settings desired to output Isometric drawings. See Index: Add New Valve Topworks...

View Article


Wiki Page: How to Modify Valve Operator Label to Show Description

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Harpreet SIngh, Bentley Technical...

View Article

Forum Post: RE: Changing the display of fasteners in AutoPLANT Modeler SS4

Thank you

View Article


Blog Post: Featured LEARNing: OpenPlant PowerPID Fundamentals; virtual class,...

OpenPlant PowerPID Fundamentals V8i Base Release, SELECTseries 5 Oct. 14-15, 2015 Finland - Helsinki time (presented in English) Ahti Mustonen OpenPlant PowerPID Fundamentals introduces the new user to...

View Article

Wiki Page: AutoPlant install fails with Error 1723

Applies To Product(s): AutoPLANT Version(s): SS4, SS5, SS6, SS7 Environment: Windows 7 64 bit Area: Installation Subarea: Error Original Author: Artiom Jakubovic, Bentley Technical Support Group...

View Article


File: Readme file for OpenPlant Modeler V8i (SELECTseries 5) Refresh update...

Readme file for OpenPlant Modeler V8i (SELECTseries 5) Refresh update for following fixes: Defect OPMS_Client: Ability to disable OPMS on per project basis OPMS_DEFAULT_CONNECTION_MODE Defect OPM_OPMS:...

View Article

Forum Post: OpenPlant Orthographics Manager V8i SS5 install issue

Hi all, I'm seeing an install failure with Orthographics Manager, message window pops up, 'OpenPlant Modeler V8i Workspace path does not exsits. Please fix the issue and rerun the Setup. OpenPlant...

View Article

Forum Post: RE: OpenPlant Orthoographics Manager V8i SS5 install issue

Hello Craig, What version of OPOM you are installing? Can you also Attach snapshot of it? Also Please mention the OpenPlant Modeler version installed in your machine. -Regards | Rahul Kumar