Wiki Page: How to Change Isometric Output Drawing Name Format
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: RE: Manully set to name isometric drawings for OPIM
Hello, Please refer below link for changing DGN output. For Project Name User need to write it inside the expression to get this so far. I Hope this helps here. Please let us know. Regards Rahul Kumar
View ArticleForum Post: RE: OPIM & ProjectWise Title Block Syncing
Hello Andrew, Thanks for reading this. Could you please describe which part in this section do you have a problem? Are you talking on Subtitle D point 7? Regards, Rahul Kumar
View ArticleForum Post: RE: OPIM & ProjectWise Title Block Syncing
Rahul, I have the attributes mapped through PW and OPIM seed file (by defining it as a tag), OPIM inserts the text per textnodes.txt into the ISO. The step I am having issues with is, getting that...
View ArticleWiki Page: Removing Spec Break Symbol in Isometric Drawing
Applies To Product(s): OpenPlant Isometrics Manager Version(s): Up to 08.11.09.404 Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: BOM or Report Generator component description is blank?
When I run a BOM for CAD or run a Report for the Report Generator the component description is coming out blank. All other fields seem to fill in correctly. Thanks for any feedback Tom
View ArticleForum Post: RE: BOM or Report Generator component description is blank?
PIPING CLASS: B1A2 PIPE Item Component Description Sch./Rating Nom. Size Quantity 1 160 3/4 0.68 m 2 160 3/4 0.68 m 3 160 3/4 0.68 m
View ArticleForum Post: RE: BOM or Report Generator component description is blank?
Hi Tom, What version of AutoPlant you are using? As well what MS Office version is installed on your side? Have you upgraded you AutoPlant version or this behavior was present from beginning? Thanks ,...
View ArticleWiki Page: Border line weight with in DWG output.
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.466 Environment: Windows 8 Area: Processing Subarea: N\A Original Author: Berrie Geboers, Bentley Technical Support Group...
View ArticleForum Post: RE: Manully set to name isometric drawings for OPIM
Thanks Rahul, I assumed that there was a way to control "FILENAME". Well, I have tried that way. It can really change Isometric DGN names, but there was a little trouble with the "Connection" lable....
View ArticleForum Post: How to fetch PIPE.WEIGHT for OPM Crystal Report
I'm working on OP Crystal Report these days. As you know, OPM utillze DRY_WEGHT as piece weight for each instance or piping component. But normally, we display WPM(weight per meter) for a pipe in MTO....
View ArticleFile: Readme for OPIM (SELECTseries 5) Refresh 2 Priority Build (Version...
Hello, Readme for the latest OpenPlant Isometrics Manager (SELECTseries 5) Refresh 2 Priority Build (Version 08.11.09.470) is available for 'Download'. Please review it for the New features and...
View ArticleForum Post: RE: BOM or Report Generator component description is blank?
AutoPlant SS4 Ver 8.11.9.210, MS Office 2007 We have not upgrade in since ss4 has come out except for maybe the version number. This workstation however had to be re-imaged a few weeks ago and this is...
View ArticleForum Post: RE: OPIM & ProjectWise Title Block Syncing
Keyin "titleblock updatedms" will write attributes to PW if thats what u want to do.
View ArticleForum Post: RE: OPIM & ProjectWise Title Block Syncing
Hello Andrew, These key in's are coming from Microstation. Make sure in Project Wise explorer you have desktop Integration supported for Microstation. Let me know if that helps! Regards, Rahul Kumar
View ArticleForum Post: Cannot connect to projects
I am trying to connect to my projects, I am asked for the username and password on the login window and push OK. Another login window appears and again I push okay; a third window appears stating "You...
View ArticleWiki Page: Managing Spec Breaks on Isometrics Drawing
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.440 & Above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Rahul Kumar,...
View ArticleComment on AutoPLANT V8i (SELECTseries 7) ReadMe Files
I recall there is a trick to viewing these files? They only open as blank files for me when I try to view them.
View ArticleComment on AutoPLANT V8i (SELECTseries 7) ReadMe Files
Right-click, properties, unblock. it takes a village.
View ArticleForum Post: RE: Instrument support tee stand, graphics or units problem for...
Sorry for late reply, As I am on leave. Thanks Aritom for your prompt response It looks you change the input and draw method for component, Please let me know why components are not drawn by reading...
View Article