Wiki Page: ATDB0755 , ATDB0816, ATDB0817

      Applies To        Product(s): AutoPLANT Piping   Version(s): 08.11.08.151   Environment:  N/A   Area:  General   Subarea:    Original Author: Artiom Jakubovic, Bentley Technical Support Group                   Problem Description Following error messages are shown when I tried to open Piping model. Project Database Warning " Atdb0755:  The following project selection will be limited to those with Metric units Do you wish to select another project to continue?  " Pressing yes will return this message once again If I press “NO” next messages will be shown: Project Database Error " ATDB0816: The current drawing has different units than the selected project Please select a project with the same units as the current document " Project Database Error " ATDB0817: Failed to initialize the AutoPlant database. This application must shutdown " As a result Piping will not load. Reason Missing Config folder from % PROJECT_ROOT% . PROJECT_ROOT is variable, which is used within AutoPlant, for project folder location   Steps to Resolve Search project root for Config folder, it could be that it was accidently dragged to other folder. Or copy Config folder from project with same configuration, in this case some additional configuration changes will be required. The changes will depend upon project configuration.  