Quantcast
Viewing all articles
Browse latest Browse all 16985

Forum Post: RE: AutoPlant Isogen error when connected to Equipment Nozzle

Hi Guys, Found the problem or rather one of my colleagues did. In the project config.ini the following appeared. [Equip.SysPaths]       ;// Equip.txtUnitsFile Units_Conversion    = %PROJECT_ROOT%\config\equip\units.ini ;// Equip.txtParamDefaults Parameter_Defaults  = %PROJECT_ROOT%\config\equip\defaults.ini ;// Equip.txtParamLimits Parameter_Limits    = %PROJECT_ROOT%\config\equip\limits.ini ;// Equipment Definition file Parameter_Templates         = %PROJECT_ROOT%\config\equip\templates.ini ;// Equip.txtMethodPath METHOD_SEARCH_PATH  = %PROJECT_ROOT%\config\equip;C:\Program Files\Bentley\Plant v8i\equip As the above was for XP we changed the last line to, METHOD_SEARCH_PATH  = %PROJECT_ROOT%\config\equip;%Network_Root%\equip Regards Ken

Viewing all articles
Browse latest Browse all 16985

Trending Articles