Wiki Page: How to change Page Connector Annotation class

      Applies To        Product(s): Bentley OpenPlant PowerPID   Version(s): 08.11.10.202   Environment:  N/A   Area:  Tags   Subarea:    Original Author: Justinas Lipnickas, Bentley Technical Support Group                     By default, annotation class for Off Page Connector is defined as PIPE_LINE_ANNOTATION class, resulting in a Size-Run-Tag string. If you would like to change it, one of the following ways should work: Steps to Accomplish Option 1 Change the annotation class for connectors Open OpenPlant_PID eschema in class editor. Supplement it with OpenPlant_PID_Supplemental_imperial eschema; Use search or browse to find OFFPAGE_CONNECTOR class; In Class tab, locate the Pipe line annotation class for connectors custom attribute class name to a desired Annotation class: Save schema, restart OPPID to see the changes. Option 2 Change the default class used for annotation: PIPE_LINE_ANNOTATION Open OpenPlant_PID eschema in class editor. Supplement it with OpenPlant_PID_Supplemental_imperial eschema; Use search or browse to find PIPE_LINE_ANNOTATION class; In properties tab of the class, find the TEXT property, change the Calculated ECProperty expression to a desired one. See Also [[OPPID - How to customize the pipeline annotation]]