Quantcast
Viewing all articles
Browse latest Browse all 16985

Wiki Page: AutoPlant SS4 installation next to AutoPlant 2004

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):AutoPLANT Piping
 Version(s):08.11.09.140
 Environment: Windows XP x32bit
 Area: General
 Subarea: 
 Original Author:Artiom Jakubovic, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

This issue appeared on Windows XP x32 bit PC with AutoPlant 2004 after installing AutoCAD 2012 + AutoPlant SS4 08.11.09.140. 

Below message was shown while trying to launch SS4 Document Manager

Image may be NSFW.
Clik here to view.


DocMgr
Run-time error ‘372’:
Failed to load control ‘TagProperties’ from APTagTree,ocx. Your version of APTagTree.ocx may be outdated. Make sure you are using the version of the control that was provided with your application.

While trying to launch AutoPlant SS4 using Plant Design for AutoCAD 2012 shortcut and loading Piping from AutoPlant 3D below messages are shown. Same messages are shown while trying to place any component in Piping model. 

Image may be NSFW.
Clik here to view.

AutoPLANT Message
Compile Error...
Script is too large to be compiled
Line: 22659
Column: 47

Image may be NSFW.
Clik here to view.

Script error
P5Y50503: Error loading script File C:\\Program Files\\Bentley\\Plant V8i\\Modules\\Base\\PIPING\\util\\ports.ebs.

Steps to Resolve

Copy DLL from attached zip BasicScript SS4.zip to C:\WINDOWS\system32. Just in case, leave existing files as back up copy.Now open CMD as administrator and re-register vsflex8l.ocx using this line:
regsvr32 C:\windows\system32\vsflex8l.ocx