Wiki Page: To Remove Area Property from Tag of Gauge Class

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Component Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Overview Modify Tag of Gauge class by removing Area property from it as shown below: Background In OpenPlant Modeler, tagging of Gauge class is defined in the supplemental schema of OpenPlant_3D schema and doesn’t inherit the tag from INSTRUMENT class which is defined in supplemental tagging schema. Below steps will be required to modify the tag. Steps to Resolve In Class editor, load OpenPlant_3D and supplement it with OpenPlant_3D_Supplemental_Modeling schema. Go to GAUGE class and switch to Properties tab. Locate NAME property on the class. In Calculated ECProperty Specification custom attribute modify both the expressions (EC and Regular expressions) to remove the highlighted portions. Final expression should look like this. Save & Close Schema. Launch OpenPlant Modeler and verify the result. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!