Wiki Page: How to add inch sign with nominal diameter in pipeline tag

$
0
0
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Properties Subarea: Original Author: Harpreet Singh, Bentley Product Advantage Group Background This article will explain how can we add inch (") sign with nominal diameter in pipeline tag. By default there is no sign with nominal diameter when it is included in Pipeline Tag, for example, pipeline tag would look like this : 4-SER-SPEC-0001. Steps to Accomplish Open class editor. Load OpenPlant.01.04 schema and supplemental it with OpenPlant_Supplemental_Tagging.01.04 schema. Go to PIPING_NETWORK_SYSTEM class. Switch to properties tab and locate NAME property. Modify the EC Expression as given below to have " sign in the nominal diameter. this.NOMINAL_DIAMETER & """" & "-" & this.SERVICE_NAME & "-" & this.SPECIFICATION & "-" & this.NUMBER Save the changes in the schema and re-open OpenPlant Modeler. Verify the Result Open a new model. Create a new pipeline through create pipeline tool. Check the pipeline Name. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!