OpenPlant Project Manager V8i SS5 Build 08.11.09.564 OpenPlant Modeler SS5 Build 08.11.09.568 Hi Rahul, Here are the Steps taken 1. Using the OP Project Manager I added the Tag Number format with EC Expressions and Validate and Save. 2. When we open OpenPlant Modeler the Tag Name fails. 3. Open the Bentley Class Editor and OpenPlant.01.06 Schema and Supplement the OpenPlant_Supplemental_Tagging.01.06. 4. Upon opening the Schemas we get following "Log" error: 2015-12-10 08:14:17,786 [1] WARN - DynamicXmlSerializer (null) - TransientLookupCollectionSerializationHandler skipping dictionary entry with key 'Bentley.ECObjects.XML.UnknownPropertyAccessor' because the value is not a serializable type. Value: UnknownXmlFragmentList 5. Navigate to Class : Plant Base Object->Named Item->Piping Network System: Property : NAME and notice there is no SymbolSet applied to the Calc. ECProperty. 6. Add manually the SymbolSet : System.String then reopen OP Modeler and the Tag Name resolves. 7. If we go back into the OpenPlant Project Administrator and make a change to the "Piping Network System" "Tag Number" Validate and save. It removes the SymbolSet we added manually. In OP Modeler the Tag Name fails.
↧