Wiki Page: ERROR DEBUG MODE Variable Is Not Defined In The Settings File Unable To Initialize Equipment Application [TN]

$
0
0
Applies To Product(s): AutoPLANT Equipment Version(s): XM, V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group Overview When a project is opened from AutoPLANT 2004 into either AutoPLANT XM or V8i, an error occurs when initializing either the Equipment or Import/Export menu. ERROR DEBUG MODE Variable Is Not Defined In The Settings File Unable To Initialize Equipment Application Open the following file in notepad: ..\project name\config\config.ini Find the following section: [Equip.SysPref] Make sure the following four lines are in this section: ;// No user interface DEBUG_MODE = 0 ;// For forward compatability with FW. Not required now but for TOOLS #2485 DEBUG = 0 Save and close. Open the model and load AUTOPLANT PIPING. Type in the following commands: (at_pipingsystem_setvariable "DEBUG_MODE" "0") (at_pipingsystem_setvariable "DEBUG" "0") Save the model and now you can load Equipment. See Also Product TechNotes and FAQs External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!