Wiki Page: ATDB0755 , ATDB0816, ATDB0817

$
0
0
Applies To Product(s): AutoPLANT Piping Version(s): 08.11.08.151 Environment: N/A Area: General Subarea: Original Author: Artiom Jakubovic, Bentley Technical Support Group Problem Description Following error messages are shown when I tried to open Piping model. Project Database Warning " ATDB0755: The following project selection will be limited to those with Metric units Do you wish to select another project to continue?" Pressing yes will return this message once again If I press “NO” next messages will be shown: Project Database Error " ATDB0816: The current drawing has different units than the selected project Please select a project with the same units as the current document " Project Database Error " ATDB0817: Failed to initialize the AutoPLANT database. This application must shutdown " As a result AutoPLANT Piping will not load. Reason Missing Config folder from % PROJECT_ROOT% . PROJECT_ROOT is variable, which is used within AutoPLANT, for project folder location Steps to Resolve Search project root for Config folder, it could be that it was accidentally dragged to other folder. Or copy Config folder from project with same configuration, in this case some additional configuration changes will be required. The changes will depend upon project configuration. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!