Hello Krishna, Though you have already ran the conversion other factors need to be considered. First you need to know what version of AutoPLANT PID this was converted from. These issues MIGHT be a result of a much older version of AutoPLANT. Second it is critical to make sure that the AutoPLANT project and drawings are in good shape. You should run all AutoPLANT diagnostics available to ensure the drawings and data are sound. Once this is complete and found to be okay, you can start the conversion process. You MUST modify the OpenPlant PID schemas to include all custom classes that were created in AutoPLANT PID. You will also need to adjust the mapping schema as required to link the custom AutoPLANT entities to valid OpenPlant Classes. I have found that OpenPlant has far more classes available than AutoPLANT did. This means that minimum configuration is required in the OpenPlant PID schemas but occasionally a custom class exist in AutoPLANT that does not have a matching class in OpenPlant. Regards, Tony DeRosa Bentley Plant
↧