Applies To Product(s): OpenPlant Modeler/OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Component Subarea: Graphics Original Author: Rahul Kumar, Bentley Technical Support Group Overview In OpenPlant Modeler Placement of tap ports on blind flange locates incorrectly. Below description will resolve the problem. Problem Description During placement of tap ports on Blind flange, user was unable to locate the tap port on face of flange. It was getting placed at its mating point of another flange. see image below. Further processing the iso sheet and generating the Isometrics produces the error as shown in below image: ERROR[0]: Tap point on component can not be associated with component segment Also see log content generated from isometrics Manager Steps to Resolve Open Spec MDB file from working project folder. Select Table 'FLANGE'. Check for Blind flange data. Enter the value for Component Length. See image below. Save & Close the spec. Launch OpenPlant Modeler. Verify results after placement. Still A Problem? If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧