Applies To | AutoPLANT ProjectWise Integration | ||
Product(s): | Project Administrator | ||
Version(s): | 08.11.09.140 and greater | ||
Environment: | N/A | ||
Area: | ProjectWise | ||
Subarea: | Integration | ||
Original Author: | Bentley Technical Support Group | ||
ERROR: Cannot find file Pwintutilsv8i.dll
Description: The error "Cannot find file Pwintutilsv8i.dll" is received during ProjectWise Integration with an AutoPLANT Project in Project Administrator and or any other AutoPLANT Application that has been previously synced.
Cause:
The issue is due to the fact that the Pwintutilsv8i.dll file cannot be found to be read into memory and or registered.
Solution:
1. Browse to the C:\PROGRAM FILES\BENTLEY\PROJECTWISE\BIN\ folder and search for the PWINTUTILSV8I.DLL file. If the file is not in this folder a repair or reinstall is required.
2. Add the C:\PROGRAM FILES\BENTLEY\PROJECTWISE\BIN\ folder pathing to the System Variable PATH section.
A. Right Click on My Computer > Properties > Advanced System Settings > Advanced tab.
B. Select the PATH variable in the System Variables section.
C. Select the Edit button and add the C:\PROGRAM FILES\BENTLEY\PROJECTWISE\BIN path into the beginning of the PATH variable value line.