Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 64 bit Area: Customization Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Introduction This article will explain the procedure of increasing the gap length between Valve and Flange for flanged valves. Steps to Accomplish Open Valves.cel file in OPPID and select End_Condition_Flange model. Move the valve cell to right by 0.01. After making changes in the cell file, open class editor. Load OpenPlant_PID.01.04 schema and supplement it with OpenPlant_PID_Supplemental_Imperial.01.04 schema. Now go to FLANGED_VALVE_END_CONDITION class under VALVE_END_CONDITIONS. 6. Go to Properties tab and select CONNECT_POINT_OFFSET property and change the default value to 0.0433. 7. Save the changes in the schema and verify the result in OPPID. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧