Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview OpenPlant Isometrics Manager missed some attributes on spool labels when processing isometric drawings. Below explanation will resolve the problem. Problem Description In user’s customized environment, default spool labels was not required and wanted to use some attributes on it along with CUTID’s. These attribute can be extracted from the data present under ‘Show Component Tag’. User has taken some information from Drawing Tag data and hence some information was missing from it. One easiest way doing this is to check what similar value has been populated between ‘Drawing Tag’ And ‘Show Component Tag’. See some sample attributes to check: Note – For LINENUMBER, writing this attribute directly on user labels does not put zero initials as 001, 002, 003 etc and keep writing as 1,2,3 and so on. See results: Spool Labels Tried by user: $(SPECMAIN)-$(FILE_NAME)-$(SERVICE)-$(LINENUMBER)-$(CUTID) Below steps will provide solution to all problems discussed above. This has been realized in context with Both AutoPLANT Modeler and OpenPlant Modeler. Below case has been taken using AutoPLANT Modeler and OpenPlant Isometrics Manager. Steps to Resolve In Class editor, Open ‘OpenPlant_3D.01.04.ecschema.xml’ and supplement it with ‘OpenPlant_3D_Supplemental_Modeling.01.04.ecschema.xml’ schema. Above schema can be found by navigating below project path : C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\YourProject\ Config\OpenPlant\schemas. Navigate to Class ‘Plant Base Object’. Right click as shown below. Copy Custom Attribute ‘Default Bill of material labels’ as below. Navigate to Piping Component class and paste as below. Default Bill of Material will get enabled. Add Element and create new attribute like shown in image below: Save & Close Schema. Launch OpenPlant Isometrics Manager. From Isometrics Configuration dialog box, open seed file using ‘Advanced’ option. Using ‘IsoExtractor’ option click on ‘Cell Creation tool’. Open ‘Annotation’ DGN file to edit the SpoolID table. Under Notes table, copy SPOOLID cell below the table. Delete the Text Spool: from the box. Place fence around the box and save the new cell to custom.cel. Save settings and close cell template DGN file. Open ‘Isometrics Configuration’ dialog and select ‘Isometric Style Tab. Under user Labels, select Pipe Spool Labels and Type the Text as mentioned below. SPOOLID:- $(IE_SPEC)-$(IE_LINENAME)-$(IE_TAGNAME)-$(CUTID) Generate isometric and verify results. It will assign spools as per CUTID and other attributes. See Also Below link on Modifying the cell template. Modifying Text and Annotation Settings Bentley Communities Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Keith... Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧