Thanks a lot for your reply! You are a real help. Can I write both A,B,C,D,E,F,G,H and RJ, RF, FF description on the same catalog or should I use only the ones from EN or ASME codes (for some flanges I have the facing type B2 and for others J ring-joint groove- I think this ones are RJ type from ASME or should i make this ones facing type H and add flanges with facing type G complementary?)? In the field FLNG_TH_M do I have to write the sum of the dimensions of the flange thickness and the raised face or the software knows by itself to sum the dimensions? Please can you confirm that the slip on flange is well defined, see attached picture. I saw that in the asme table there is a field SETBACK, it is the field that describes the welding space from the front of the flange? Can i put this value in the HUB_DEPTH or in the SKT_DEPTH_R field or should i add a new field called SETBACK to my table?
↧