The fields for socket depth do not seem to be included in the base DIN catalog because none of the base components included a fitting with a socket weld end type. Add the following fields to the table to indicate the socket depth: Main port depth = SKT_DPTH_M Run port depth = SKT_DPTH_R Branch port depth = SKT_DPTH_B I also recommend editing the table using openplant Specification generator to avoid any errors that may be introduced by manual editing.
↧