Wiki Page: How to Compress Welds for Slip On Flange

$
0
0
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 & Above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Technical Support Group To Compress Welds on Slip On Flange in OpenPlant Isometrics Manager. Background Using AutoPLANT Modeler and OpenPlant Isometrics Manager, Slip on flanges provides two welds on isometrics. See image below. In some cases, it has been required to get single weld isometrics. Below steps will aid user to compress double weld to single. Steps to Accomplish From working project navigate to style folder. See below default path for reference C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant \Isometrics \styles\IFC\config\style.cfg Open Style.cfg file. Check for variable ‘Compresswelds’ and change value from 0 to 1. See image below. Save & close file. Generate Isometrics and verify result. See image below. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!