Wiki Page: Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when branch connected through Stub-In tapport

Applies To Product(s): OpenPlant Isometrics Manager & AutoPlant Modeler Version(s): 08.11.09.458 & 08.11.11.135 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Problem Description Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when branch connected through Stub-In tapport Steps to Resolve Open Class Editor and go to File>Open navigate to project path. Open ‘OpenPlant_3D.01.04.ecschema.xml’ & supplement it with ‘OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04.ecschema.xml’ Schema. 3. Search TAP_CONNECTION class. 4. Change the value in “Item Code” from this.COMPONENT_NAME to “TAG” (add the string quotes around TAG). 5. Save the schema. 6. Restart document manager generate isometric to review the result. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!