Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley Technical Support Group Dimensioning Dimension Styles Dimension definitions (styles) are configured in the isometric seed file. Although several dimension styles can be defined, the “active” style is the one used when generating the isometric drawing. Stacked Fractions and Degree Symbol A limited set of MicroStation fonts support the display of stacked fractions. An appropriate font must be set in the Text tab of the Dimension Style dialog. "1 WORKING" and "32 INTL_ENGINEERING" are examples of fonts that support stacked fractions Dimensioning Gaskets Gasket dimensions are controlled by a switch in each Isometric Style. The default setting is to not include gasket dimensions. Use the steps below to modify the switch. Open the Isometrics Configuration tool From the Isometric Configuration dialog: Select the Isometrics Style tab Style – Select the relevant style from the dropdown Select Converter Settings from the tree Disable Skip Gasket Dimensions Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧