It seems that for some reason,
every time I place a pipe run in autoplant, it creates two entries in the
database for that line.
There have also been a number of
instances where it creates a pipe run on a different spec for the same line
run.
Also, anytime my autoplant
freezes up, which has primarily been when I use the “catt” command, I close out
of the drawing and re-open it, and my pipe/components are gone from the
p&id, but remain in the database, causing me to have to create an
additional link to redraw those line run/components.
The “purge orphaned data”
command does nothing.