Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Background How to show Miscellaneous Attachment (Test Port Instrument Bubble) with tag number in isometric. Steps to Accomplish 1. Open class editor and navigate to project path and open schema.“OpenPlant_3D.01.04.ecschema.xml” For ex. C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\schemas. 2. Supplement this schema with “OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04.ecschema.xml”. 3. Now search “Note” class found under Plant base object>Named Item. 4. Under note class create new class by using “Add derived class” option. 5. Assign name “Instrument_BUBBLE”. 6. Now right click on wall penetration copy custom attributes. 7. Paste this custom attributes on Instrument Bubble class. 8. Edit the AutoPLANT class name refers below image. 9. Add new property TAG_CODE. 10. Add Custom attribute ‘AutoPLANT_PDW_Property_Map’ on ‘TAG_CODE’ property to map AutoPLANT property with OpenPlant property. See image below. Set Schema location as’ OpenPlant_3D.01.04.ecschema.xml’ 11. Save and close schema. 12. Launch OpenPlant Isometrics Manager. Click on configuration button. See image below. 13. Add new label ‘Instrument Bubble’ here. 14. Edit as per below image. 15. Save and close. 16. Generate isometric to review the result. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧