Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Processing Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Problem Description When generate isometric through OPIM, it count ‘UBR_STUB_IN’ in bill of material, however some of user requirement is to add only reinforcement pad in bill of material. Following illustrative steps will helps to suppress UBR_STUB_IN material from BOM and remove related ‘part id’ from isometric. Steps to Resolve Launch OpenPlant Isometrics Manager. From Configuration settings, open Isometric Dialog. From Advanced node, click on ‘Open Report definition’ file. See image below. Note: For AutoPLANT user, reportdef file can be open by navigating to project path under style>config Folder, C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant \Isometrics \styles\IFC\config\report.def 4. Edit report definition file as per below image. 5. Save and close the file. 6. Now open ‘rep_sortgroups.txt’ file in notepad. 7. Edit entry as per below image. 8. Save and close the file. 9. Generate isometric to review the result. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!