Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Technical Support Group In OpenPlant Isometrics Manager, BOM report information may varies with respect to types requirement of the project, namely say FABRICATION, ERECTION, CONTINUOUS types. Background In OpenPlant Isometrics Manager, using OpenPlant Modeler/AutoPlant Modeler various BOM report types required as mentioned above. It can be achieve through modifying report.def file under style folder present under each project. Various types of reports can be created and stored under style folder, which can be later utilized by renaming the files by user. Below information will help user to achieve various types of settings.It can be experienced using both OpenPlant modeler and AutoPlant Modeler. This has been shown in context with OpenPlant Modeler and OpenPlant Isometrics Manager. However similar approach could be utilized for AutoPLANT modeler and OpenPlant Isometrics Manager, using the isometric Configuration dialog, either using in session from project administrator or from out session using start menu and launching OpenPlant Isometrics Manager. Steps to Accomplish 1. For any FABRICATION report use these filters INCLUDE = IE_FIELD=0 EXCLUDE = IE_TYPE=CT_WELD Note: Disable other available report, say FLD by adding # value as a prefix and keep the node number under Combi report (Optional). See image below. Save and Close report file and generate isometrics to verify results: 2. For any ERECTION report use these filters INCLUDE = IE_FIELD=1 EXCLUDE = IE_TYPE=CT_WELD Note: Disable other available report, say SHP by adding # value as a prefix and keep the node number under Combi report (Optional). See image below Save and Close report file and generate isometrics to verify results: 3. For a CONTINUOUS report use this filter: EXCLUDE = IE_TYPE=CT_WELD In order to get a continuous numbering sequence, IE_PARTID_SF_COMBINED=1 should be set in style.cfg. See below image. Save and Close report file and generate isometrics to verify results: See Also Configuring the BOM and Reports - http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12642.configuring-the-bom-and-reports Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧