Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 64 bit Area: Component Subarea: Data Original Author: Harpreet Singh, Bentley Technical Support Group Introduction In OPPID, when control valve is placed an actuator is also placed with it and control valve's tag is annotated on the instrument bubble but if user also wants a separate tag for only Motor Operator (Actuator) then there is no direct way because there is no relationship between the valve and actuator. Since actuator is a part of Valve cell and not a separate instance therefore we need an indirect way of annotating the actuator with different tag. Steps to Accomplish Open class editor and load OpenPlant_PID schema. Supplement it with OpenPlant_PID_Supplemental_Imperial schema. Go to THREE_WAY_CONTROL_VALVE class and create new property 'MOTOR_NUMBER. Create another property ACTUATOR_TAG on THREE_WAY_CONTROL_VALVE class. Add a Calculated EC Property Specification attribute on ACTUATOR_TAG property and set EC Expression as highlighted below. Please Note: The EC expression shown above will calculate the tag only if the Actuator type is 'Motor Operator'. If you want the tag for all actuator types then please check this page Actuator Tag not Placed with Control Valve Add Annotation Custom Attribute and set the count to 1. Save the changes in schema and verify the result in OPPID by placing a three way valve with Motor Operator. See Also For similar customization on Actuator Tag on control valve, check below links: Actuator Tag not Placed with Control Valve- http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/18620.actuator-tag-not-placed-with-control-valve Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧