Wiki Page: To Fix Sheet Number Continuation Labels in OpenPlant Isometrics Manager

$
0
0
Overview For Bentley OpenPlant Isometrics Manager Continuation labels information on isometrics is required to get the connectivity information for its branch/connected lines in Isometrics. Problem Description In Bentley OpenPlant Isometrics Manager, continuation label information does not appear to the connected sheet if the main/header sheet does not run at the same time. This is happening when generating the Isometrics through connecting OpenPlant Model server database. Using an I-Model by including all the lines, continuation labels appear without running the lines together. Steps to Resolve Open Class Editor. Open schema “OpenPlant_3D_Supplemental_Model_Server.01.04.ecschema.xml”. Change backward query depth of NAMED_ITEM from 3 to 1. Refer snapshot below. Save the changes and close it. Check out your pipe and check in. Generate Iso through OPIM. You will get the continuation for pipes. See Image below. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!