Wiki Page: Piping Components Do Not Fetch Rating Value From Spec

$
0
0
Applies To Product(s): Bentley OpenPlant Modeler Version(s): 08.11.09.404 Environment: Windows 7 64 bit Area: Component Subarea: N/A Original Author: Harpreet Singh, Bentley Technical Support Group   Problem Description User reported that RATING value in his spec reads 150LB but when placing the components in OPM it is taking the RATING as CL150 which conflicts the spec and their requirement. It is happening because the RATING property on the PIPING_COMPONENT class is mapped with RATING_VALUE_MAP which contains the rating values as CL150, CL300, CL600..and so on.          Steps to Resolve Launch Class Editor and load OpenPlant_3D.01.04 schema. Supplement it with OpenPlant_3D_Supplemental_Modeling.01.04 schema. Go to PIPING_COMPONENT class and select RATING property. Set the 'IsValueToBeMapped' to FALSE in OpenPlant_Physical_Catalogue_Property_Map custom attribute. Save the changes and verify the result in OPM.