Applies To Product(s): Bentley OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 32 bit, Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group Background When using OpenPLANT Isometrics Manager with AutoPLANT it will show flow arrow symbol in the isometrics like below. This can be easily removed if it is unwanted by removing the description of the flow arrow from the AutoPLANT CLASS.ini file. By default the flow arrow's have description i.e. Flow Arrow. To see this double click or perform edit component on a flow arrow inside the AutoPLANT model as below: Steps to Accomplish: Open CLASS.ini file from C:\Program Files (x86)\Bentley\Plant V8i\Modules\Base. Search AT_ATTACH_FLOW and change the LONG_DESCR to below: See the results below after the changes:
↧