Wiki Page: Connecting flanges with different ratings

$
0
0
Applies To Product(s): AutoPLANT Piping/Modeler Version(s): AutoPLANT XM,V8i Environment: Windows 7/XP 32/64 bit Area: General Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group               Some changes is needed in the files to connect flanges with different ratings. To accomplish the same. Please follow the steps below:   Make sure component with different ratings are present in the spec. To make the customization project specific copy joints.ebs to ..\%PROJECT_ROOT%\%PROJECT_NAME\Config\modules\ Open Joints.ebs and find below: If (CheckPCL(currPCL,connPCL) And CheckFAC(currFAC,connFAC)) Then   Change it to : If CheckFAC(currFAC,connFAC) Then   4. Save and close the file. See below you will be to select flanges with different ratings.  