Wiki Page: Standard U Bolt Support Placement

$
0
0
      Applies To        Product(s): AutoPLANT Piping   Version(s): 08.11.09.140   Environment:  Windows 7 64 bit   Area:  Component   Subarea:  Placement   Original Author: Artiom Jakubovic, Bentley Technical Support Group       Do not take into account insulation thickness while placing Standard U Bolt support. Background During default placement routine, Standard U Bolt placement takes into account insulation thickness and shows in U Bolt Support dialog U Bolt Radius equal to Pipe Radius + Insulation Thickness radius Steps to Accomplish Open C:\Program Files (x86)\Bentley\Plant V8i\Modules\Base\common\SUPUBOLT.EBS Find at_Support_UBolt routine, line173 Comment 266, 267,268, 270 lines as it shown on picture below.  After this the U bolt radius will show only pipe radius with 0.02 % increase despite presence of insulation. 